Fuel Level Transmitter



Capacitance Level Transmitter is a compact, low cost, level transmitter with analogue out~put designed to measure the level Of various non viscous, non conductive fuel oils, such as Diesel. Measuring range is 0.2 to 2 m for rod probe version. The probe forms an electrical capacitor with the grounding stell well provided on the sensing rod With the vessel empty, an initial capacitances exists between the electrode And the metal well or the auxiliary reference probe. When the probe become covered with material to be measured the capacitances will increase and change will be measured and convered into an analogue output signal proportional to the change. 

 

SALIENT FEATURES :

  • Fast and Easy Installation No Calibration. Prc calibrated for each probe length.
  • N0 etfect of terbulance in the tank.
  • High Reliability
  • Suitablc for the highly dusty environment.
  • Provides economical solutions.

 

MEASURING SYSTEM :

  • The complete system, FUELTRANCE - 5000... series, consists of :-
  • The sensing probe with integral electronic mounted on the probe head, encapsulated.

 

APPLICATIONS :

  • Fuel Level Sensor capacitance fuel trance is designed for diesel.
  • Fuel Level measurement in Fuel tank ofvehicles and stationary units.
  • It is prohibited to use fueltrancc for level measurement of electrically conducting liquids(e.g. water)

 

SENSING PROBE :

  • Mounting : Screwed 3/4" BSP Or Flanged (Optional)
  • Sense : Pipe / Rod stainless steel (SS 304)
  • Grounding : Pipe , SS 304
  • Length : 175 (Standard) upto 2000 mm

 

MODELS :

  • FUELTRANCE 5105 : OUTPUT : 0-5 V DC (3-Wire)
  • FUELTRANCE 5110 : OUTPUT : 0—10V DC (3-wire)
  • FUELTRANCE 5120 : OUTPUT : 4-20 mA (2-wire)
  • FUELTRANCE 5435 : OUTPUT : RS485 & 0-5 V DC (4-Wire)

 

PRIMARY APPLICATIONS :

Non-Conductivity material : Mostly petrochemical and solvents insulated or non-insulated can be used


Specifications

Housing Cast Aluminum, weatherproof
Mains 12 V DC to 30 V DC
Current Consumption 20 mA (max)
Responce Time Better Than 10 Sec
Operating Temp 20 to +60 Deg. C
Signal output 0 to 5 V DC or l0 V DC, RS 485 /4-20 mA DC
Mounting Screwed 3/4" BSP or Flanged (Optional)
Range Setting Digital Setable
Accuracy Standard 4mm, 3 Mm (special)


Contact Us

Jaycee Technologies Pvt. Ltd.

Shed No.7, Nanekar Industries Building Survey No. 79/2, Dangat Industrial Estate Shivane , Pune -411 023, India., Shivane, Pune, Maharashtra - 411038, India

Mobile : +91-8554982251

Phone : +91-20-64703186

Fax : +91-20-25290744

Call Us : 08045132595



Looking for Product Name ?