Product Details

Range 5M, 10M, 15M, 20M, 30M, 50M, 70M
Power Supply 24-VDC,120mA/ 12VDC
Relay /Alarm Output AC 25OV/ 8A, DC30V/ 5A (Optional)
Accuracy 0.2%--0.5% F.S
Blind Zone 0.2%-0.6m
Working Pressure 2 Bar
Resolution 3mm or 0.1%F.S (Max of them)
Environment Tem. Sensor -20~+8O
Digital Output RS485 (Optional)
Water proof IP65
Sensor Installation Screwed, top mounted

SALIENT FEATURES :

  • Strong, stable sensor suitable for harsh industrial situation
  • Strong anti-interference, can be arbitrarily set the upper and lower nodes and on-line output regulation
  • Transducer builtin temperature sensor, to achieve real-time measurement of the value of automatic temperature compensation
  • Blind spots can also be manually set, shielding the probe near the interference signal
  • 4 - 20MA current output, optional field bus interface

 

APPLICAI IONS :

  • Water and waste water treatment
  • Pumping station, collection wells, biochemical reaction tank, sedimentation tanks, etc.
  • Electric power, mining mortar pool, coal slurry pond, water treatment, etc.

 

Display :

LCD display - Level distance, ...

Read More...


Yes! I am interested


Split Type Ultrasonic Open Channel Flow Meter
Send Enquiry

Product Details

Range 5M, 10M, 15M, 20M, 30M, 50M, 70M
Power Supply 24-VDC,120mA/ 12VDC
Relay /Alarm Output AC 25OV/ 8A, DC30V/ 5A (Optional)
Accuracy 0.2%--0.5% F.S
Blind Zone 0.2%-0.6m
Working Pressure 2 Bar
Resolution 3mm or 0.1%F.S (Max of them)
Environment Tem. Sensor -20~+8O
Digital Output RS485 (Optional)
Water proof IP65
Sensor Installation Screwed, top mounted

SALIENT FEATURES :

  • Strong, stable sensor suitable for harsh industrial situation
  • Strong anti-interference, can be arbitrarily set the upper and lower nodes and on-line output regulation
  • Transducer builtin temperature sensor, to achieve real-time measurement of the value of automatic temperature compensation
  • Blind spots can also be manually set, shielding the probe near the interference signal
  • 4 - 20MA current output, optional field bus interface

 

APPLICAI IONS :

  • Water and waste water treatment
  • Pumping station, collection wells, biochemical reaction tank, sedimentation tanks, etc.
  • Electric power, mining mortar pool, coal slurry pond, water treatment, etc.

 

Display :

LCD display - Level distance, ...

Read More...